Hydrogen Oxygen Gas Flow Meter Controller Vacuum Coating Machine For Air

Ask Latest Price
Video Channel
Brand Name :YunYi
Model Number :MFC1000
Place of Origin :China
MOQ :1 piece
Price :USD769.0 - 886 PER PIECE
Payment Terms :T/T, Western Union, D/A, D/P
Supply Ability :100 Unit/Units per Week
Delivery Time :7days
Packaging Details :in Standard carton box
Product name :Hydrogen Oxygen Mass Flow Controller for Nitrogen
Type :Variable Area Air & Gas Flowmeters
Measuring Range :20 / 50 / 100 / 200 / 500 / 1000 sccm, 2 / 5 / 10 / 20 / 5
Accuracy (under calibration condition *) :+-(1.5% +0.5%FS)
Repeatability :±0.5%FS
Zero drift full range drift :0.5%FS/ Year
Working range \range adjustable ratio :100:1
Maximum controllable flow :102%FS
Typical response time :100MS
Start up time :70MS
Working temperature :0-+50℃
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

Hydrogen Oxygen Gas Flow Meter Controller Vacuum Coating Machine For Air

Description Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

The MFC1000, use of packaging technology makes it possible to measure different ranges of flow under the same pipe diameter, and mass production ensures high ridiculousness, high performance and low cost.
Products calibrated with air are switched to argon, carbon dioxide, oxygen or carbon monoxide (laughing gas) by the gas selection command.
A wide range of applications, one set to handle multiple working conditions. Gas medium: air, nitrogen, oxygen, argon, hydrogen, carbon dioxide, and other dry, clean and non-corrosive gases

Technical Specification Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

Data Numerical value
Measuring Range 20 / 50 / 100 / 200 / 500 / 1000 sccm, 2 / 5 / 10/ 20/50SLPM
Accuracy (under calibration condition *) +-(1.5% +0.5%FS)
Repeatability +-0.5%FS
Zero drift full range drift 0.5%FS/ Year
Working range range adjustable ratio 100:1
Maximum controllable flow 102%FS
Typical response time 100MS
Start up time 70MS
Working temperature 0-+50℃
* Temperature drift: with the calibration temperature S0℃ each time of difference, accuracy increased 0.12%

Product model

Full range pressure loss vented to atmosphere

The equipment size mm3

Pipe connection

MFC1000-20/50sccm 200Pa

63.5*66.5*22.5

1/8”NPT female

MFC1000-100/200sccm 1000Pa
MFC1000-500/1000sccm 1000Pa
MFC1000-2/5SLPM 5kPa 70.5*74.2*26.0 3/8”NPT female
MFC1000-10/20SLPM 35kPa
MFC1000-50SLPM 50kPa 101.5*68.5*35.0 3/8”NPT female

Dimension Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

Hydrogen Oxygen Gas Flow Meter Controller Vacuum Coating Machine For Air

Max Allowable working pressure Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

The maximum allowable working pressure:


MFc1000.20/50/100/200/500/1000sccm:2/5sLpM:145psig(1Mpa) MFc1000.10/20/50sLpM:59psig(0"4Mpa)


If the pipeline pressure is higher than the maximum working pressure, please add a pressure regulator at the front of the air inlet to adjust the pressure below the maximum working pressure.

Order Guide Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

Hydrogen Oxygen Gas Flow Meter Controller Vacuum Coating Machine For Air

Installation Precautions & Pipe Connection Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

Installation Precautions
Insrtal MFc1000The hole at the bottom of the series mass flow controller is used for equipment installation and fixation, the thread size is M3. No straight pipe segment is required for the inlet or outlet pipes of the device.
Pipe connection
Ensure that the air flows in the same direction as the arrow on the device.
The inlet and outlet sizes of the equipment (connected to the process system) are 1/8 "NpT or 3/8"NpT female threads.
We recommend that you use teflon tape wound seal to prevent thread leakage.
Do not entangle the raw material belt on the two threads nearest to the equipment body, so as to minimize the possibility of the raw material belt being involved in the equipment body.
Do not use paint or sealants at the connection between equipment and process piping. Such compounds entering the equipment body will cause permanent damage to the mass flow controller.When replacing the joint, please carefully clean the residual raw tape and debris of the thread orifice.

Application Hydrogen Oxygen Vacuum coating machine Gas mass flow controller for air

Hydrogen Oxygen Gas Flow Meter Controller Vacuum Coating Machine For Air

Hydrogen Oxygen Gas Flow Meter Controller Vacuum Coating Machine For Air

Inquiry Cart 0