1. Key parameters for selection
Diameter: DN4~DN200 (common).
Flow range: needs to be selected according to the minimum/maximum flow rate.
Medium characteristics: viscosity (usually <5cP), temperature, corrosiveness.
Pressure level: determined according to pipeline pressure.
Output requirements: whether on-site display or remote communication is required.
2. Installation requirements
Straight pipe section: upstream ≥10D, downstream ≥5D (D is the pipe diameter).
Avoid vibration: prevent bearing wear.
Full pipe state: ensure that the pipe is full of liquid when installed horizontally.
Filter: It is recommended to install it in front to prevent impurities from damaging the turbine.